Best Portable Power Stations for Home Backup
Published 23 Nov 2026
We earn from qualifying purchases. Links to Amazon and brand stores on this page are affiliate links; buying through them supports the site at no extra cost to you. How this works.
Key takeaways
- Size the battery from average watts, not nameplate running watts: usable energy is 85% of rated watt-hours after inverter losses.
- A typical refrigerator is often fine on a 1,800 W class station, but the energy budget is tight. Plan about 60 W average if a 150 W compressor runs 40% of the time.
- A CPAP without a heated humidifier often averages about 40 W and wants a 1 kWh-class station for a comfortable night plus margin. With the humidifier, plan closer to 80 W.
- Prefer LiFePO4, a published UPS/EPS switchover time if you will protect a modem, office PC, or CPAP, and expansion batteries if a storm can last more than a day.
- Plug appliances directly into the station, or use a transfer switch or interlock installed by an electrician. Never back-feed the house through a wall outlet.
Who needs what
A portable power station is a battery and inverter in one box. Used indoors, it can keep a few essential circuits running when the grid drops, without the exhaust and placement rules of a fuel generator. The right size depends on two separate questions: can it start and run the load, and how many watt-hours will that load use before the battery is empty?
Use these planning tiers with the catalog models in this guide. They are starting points, not guarantees, because every appliance's real draw is on its label.
Router, modem, lights, and phones (about 15–50 W combined). A compact station in the 300 Wh class can cover a day of communications and charging. The EcoFlow RIVER 3 Plus sits in this tier.
CPAP. Without a heated humidifier, many units average about 30–50 W. We use 40 W in the runtime math below. An 8-hour night at 40 W needs about 376 Wh of usable energy, so a 1 kWh station is the comfortable starting point and can cover two nights. With a heated humidifier, many units average closer to 80 W, which is one long night on a 1 kWh pack and two nights on a 2 kWh pack. Prefer a published UPS or EPS switchover if the machine should stay running when the grid falls over.
Refrigerator. A household fridge often draws about 150 W while the compressor is on and sits idle the rest of the time. A common planning assumption is a 40% duty cycle, or about 60 W average. Starting current is often two to three times running watts, so look for at least about 1,500–1,800 W continuous and a published surge rating in the 2,700 W and up range. Energy-wise, a 1 kWh station can cover roughly half a day to a day; a 2 kWh station can cover about a day and a night.
Sump pump. This is the demanding case. Many portable pumps draw 800–1,500 W while running and two to three times that to start. The station has to cover the surge, not just the average. During a storm a pump may only run a few minutes each hour, but if it cannot start, the average does not matter. Pair a high-output station (about 2,000 W continuous or more, with a published surge of about 4,000 W or higher) with enough watt-hours for the hours you expect it to cycle. For whole-home 120/240 V pumps, look at the larger home-backup units later in this guide and a properly installed transfer switch.
If you want to test your own mix of loads, use the load calculator.
How we pick
We only compare products that are already in the Power That Lasts catalog, and we use the manufacturers' published figures. A few rules keep the comparison honest:
- Capacity (Wh). Runtime starts here. We treat 85% of rated watt-hours as usable, to allow for inverter losses, and we state the load assumption next to every estimate.
- Continuous and surge watts. Continuous output has to cover running watts. Surge (or a maker's published peak) has to cover motors and compressors at start-up. We do not treat X-Boost or power-lifting modes, which often lower voltage to run certain high-wattage heating loads, as the same thing as surge.
- LiFePO4 chemistry. Every station in this guide uses LiFePO4 (LFP) cells. Cycle-life figures are only used when the maker rates them to 80% capacity. If a maker rates cycles to 70%, we leave that field blank and say so in the text.
- UPS or EPS switchover, in milliseconds. This matters if a CPAP, modem, or desktop should ride through the outage instead of rebooting. Leave the station plugged into the wall and plug the protected device into an AC outlet on the station, then test it. These are not 0 ms data-center UPS units unless the maker explicitly publishes a 0 ms online-UPS mode.
- Solar input. Maximum solar watts and the allowed voltage window decide whether portable panels can refill the battery during a multi-day outage.
- Expandability. A 1 or 2 kWh pack that accepts official extra batteries can grow for a longer storm. Several popular mid-size models cannot.
We do not invent ratings, and we do not quote prices in this article. The product cards and tables show the current offer.
The picks
-
Apartment or small-load backup, mostly a router, lights, and phonesEcoFlow RIVER 3 Plus — compact 286 Wh pack with a 10 ms UPS, used as a point backup rather than a whole-kitchen battery
-
CPAP or a refrigerator through a short outageEcoFlow DELTA 3 Plus — 1,024 Wh, 1,800 W, 10 ms switchover, and official expansion up to 5,120 Wh
-
Lightest 1 kWh station to carry upstairsJackery Explorer 1000 v2 — 1,070 Wh and 1,500 W at 23.8 lb, but it does not accept extra batteries
-
Multi-day essentials with room to add batteriesEcoFlow DELTA 2 Max — 2,048 Wh, 2,400 W, and official expansion to 6,144 Wh
-
Higher 2 kWh output without expansionBLUETTI Elite 200 V2 — 2,073 Wh and 2,600 W continuous, with a 15 ms UPS
-
120/240 V whole-home portable backupEcoFlow DELTA Pro 3 — 4,096 Wh and 4,000 W, with larger alternatives below if you need more output or capacity
EcoFlow RIVER 3 Plus — compact point backup
This is the small station in the group: 286 Wh, 600 W continuous, a 10 ms UPS, and about 10.4 lb, with official expansion to 858 Wh. It is the right tool when you mainly want to keep a modem and router, some lights, and phone charging online, or to sit next to a desk as a UPS.
It is not a home-backup battery in the refrigerator sense. At 600 W continuous it will not start many fridges or pumps, and the official US specifications do not list a separate surge rating (they do describe X-Boost for certain loads up to 1,200 W, which is not the same as surge). For an 8-hour CPAP night at 40 W, 286 Wh is also tight once you apply the 85% rule.
Who it is for: apartments, dorms, or a dedicated UPS for communications and a home office.
The downside: the 600 W inverter and 286 Wh pack are too small for a refrigerator or a reliable full-night CPAP at 40 W.
EcoFlow DELTA 3 Plus — the 1 kWh home-essentials pick
For most households buying a first station to cover a fridge, a CPAP, and the internet, this is the most complete 1 kWh option in the catalog. It has 1,024 Wh, 1,800 W continuous, 3,600 W surge, a 10 ms UPS, up to 1,000 W of solar input, and official expansion to 5,120 Wh. It also recharges from AC in 56 minutes, which matters if you have a generator or the grid comes back in bursts.
Who it is for: a house or apartment that needs a refrigerator and a CPAP through a short outage, with a path to add batteries later.
The downside: 1,024 Wh is still about a day of a typical fridge, not a multi-day storm, unless you buy the extra batteries.
Two close 1 kWh alternatives are worth a look if this one is not the right shape for you.
The Jackery Explorer 1000 v2 is the lightest 1 kWh station here at 23.8 lb, with 1,070 Wh, 1,500 W continuous, 3,000 W surge, and a 20 ms UPS. Jackery officially rates its cycle life to 70%+ capacity, not 80%, so we do not record a cycle-life figure for it. It is also not expandable. Choose it when you will carry the station often and do not plan to add batteries.
The BLUETTI AC180 offers 1,152 Wh, 1,800 W continuous, 2,700 W surge, and a 20 ms UPS, with a 5-year warranty. BLUETTI's official FAQ says it cannot take B80, B230, or B300 batteries as expansion packs (they can only recharge it in power-bank mode), and the app connects over Bluetooth only, with no Wi-Fi. It is a solid standalone 1 kWh box, not a system you grow.
The Anker SOLIX C1000 is the expandable alternative in this size: 1,056 Wh, 1,800 W continuous, a 20 ms UPS, and official expansion to 2,112 Wh. Its published surge is 2,400 W, the lowest in this 1 kWh group, so it is a weaker match for a pump or another hard-starting motor.
BLUETTI Elite 200 V2 — high-output 2 kWh, no expansion
When the job is a refrigerator plus a sump pump or a couple of kitchen appliances, inverter headroom matters as much as watt-hours. The Elite 200 V2 publishes 2,073 Wh, 2,600 W continuous, 3,900 W surge, a 15 ms UPS, 6,000 cycles to 80%, and up to 1,000 W of solar. It is one of the strongest 2 kWh inverters in the catalog.
Who it is for: households that want a single 2 kWh station with enough continuous output for a pump or several large appliances at once, and that will not add extra batteries.
The downside: it is not expandable, and at 53.4 lb it is a two-handed carry.
EcoFlow DELTA 2 Max — expandable 2 kWh for longer outages
The DELTA 2 Max is the 2 kWh station to pick if the outage may last more than a day. It has 2,048 Wh, 2,400 W continuous, 4,800 W surge, up to 1,000 W of solar, and official expansion to 6,144 Wh with two extra batteries. The UPS is 30 ms, which is slower than the 10–15 ms on the newer units above, so test it with any sensitive device you need to keep up.
Who it is for: homes that want a 2 kWh starting pack and a clear official path to about 6 kWh.
The downside: the 30 ms switchover is slower than EcoFlow's newer 10 ms units, and the 50 lb box is heavier than the Jackery 2 kWh option below.
The Jackery Explorer 2000 v2 is the lighter 2 kWh alternative at 39.5 lb, with 2,042 Wh, 2,200 W continuous, 4,400 W surge, and a 20 ms UPS. Like the 1000 v2, it is not expandable, and Jackery rates its cycle life to 70%+ rather than 80%. Take it when portability matters more than adding batteries.
Larger portable home-backup systems
If you want 120/240 V output, a path to a transfer switch, or several days of essential loads, the catalog's home-backup units are the next step. They are still portable in the sense that they are not a permanently installed wall battery, but they are 80–140 lb machines, not carry-on bags.
The EcoFlow DELTA Pro 3 is the most direct step up: 4,096 Wh, 4,000 W continuous, 8,000 W surge, a 10 ms UPS, up to 2,600 W of solar, and official expansion to 12,288 Wh. It can support a transfer switch for selected circuits. At 113.5 lb it is not a one-person lift. EcoFlow publishes an AC charge to 80% in 50 minutes, but not a single time to 100%, so we leave that figure blank.
| Product | Capacity | Output | Chemistry | AC charge | Solar in | Price |
|---|---|---|---|---|---|---|
| EcoFlow DELTA Pro 3 EcoFlow | 4,096 Wh | 4,000 W | LiFePO4 | — | 2,600 W | Check price |
| BLUETTI Apex 300 BLUETTI | 2,765 Wh | 3,840 W | LiFePO4 | — | 2,400 W | Check price |
| Jackery Explorer 5000 Plus Jackery | 5,040 Wh | 7,200 W | LiFePO4 | 210 min | 4,000 W | Check price |
| Anker SOLIX F3800 Plus Anker | 3,840 Wh | 6,000 W | LiFePO4 | — | 3,200 W | $2,999.00 |
-
EcoFlow DELTA Pro 3 EcoFlow
- Capacity
- 4,096 Wh
- Output
- 4,000 W
- Chemistry
- LiFePO4
- AC charge
- —
- Solar in
- 2,600 W
-
BLUETTI Apex 300 BLUETTI
- Capacity
- 2,765 Wh
- Output
- 3,840 W
- Chemistry
- LiFePO4
- AC charge
- —
- Solar in
- 2,400 W
-
Jackery Explorer 5000 Plus Jackery
- Capacity
- 5,040 Wh
- Output
- 7,200 W
- Chemistry
- LiFePO4
- AC charge
- 210 min
- Solar in
- 4,000 W
-
Anker SOLIX F3800 Plus Anker
- Capacity
- 3,840 Wh
- Output
- 6,000 W
- Chemistry
- LiFePO4
- AC charge
- —
- Solar in
- 3,200 W
The BLUETTI Apex 300 (2,765 Wh, 3,840 W, expandable to 21,196 Wh with official extra batteries) is the most expandable of the four and can be paralleled into a larger 120/240 V system. The Jackery Explorer 5000 Plus (5,040 Wh, 7,200 W) has the largest built-in battery and 0 ms online UPS / under 20 ms backup UPS, but Jackery rates its cycle life to 70%+ and the unit weighs 134.5 lb. The Anker SOLIX F3800 Plus (3,840 Wh, 6,000 W, expandable to 26,880 Wh) is the highest-output Anker in the group; its 120 V AC input is 1,800 W maximum, so a full recharge from a standard wall outlet is published as under 3 hours rather than a precise time to 100%.
Who the DELTA Pro 3 is for: a house that will put several essential circuits on a transfer switch and may add extra batteries later.
The downside: 113.5 lb, and you still need an electrician for any connection to house wiring.
How long will it actually run?
We use the same planning rule everywhere: usable energy is 85% of the maker's rated watt-hours, and runtime is usable watt-hours divided by the appliance's average draw. Real runtime varies with temperature, battery age, and inverter efficiency, so treat these as planning numbers, not promises.
Assumptions used below:
- Refrigerator: 150 W while the compressor runs, 40% of the time, or 60 W average.
- CPAP without a heated humidifier: 40 W average. With a heated humidifier: 80 W average.
- Router and modem: 15 W combined, continuous.
- Sump pump: 800 W while running, 10 minutes each hour during a storm, or about 133 W average. The station must still cover the start-up surge when the motor kicks on.
| Station | Usable energy (85%) | Fridge at 60 W | CPAP at 40 W | CPAP at 80 W | Router at 15 W | Sump at 133 W avg. |
|---|---|---|---|---|---|---|
| EcoFlow RIVER 3 Plus (286 Wh) | 243 Wh | 4.1 hours | 6.1 hours | 3.0 hours | 16 hours | Not a fit (600 W inverter) |
| EcoFlow DELTA 3 Plus (1,024 Wh) | 870 Wh | 14.5 hours | 21.8 hours | 10.9 hours | 58 hours | 6.5 hours, if it can start the pump |
| Jackery Explorer 1000 v2 (1,070 Wh) | 910 Wh | 15.2 hours | 22.7 hours | 11.4 hours | 61 hours | 6.8 hours, if it can start the pump |
| BLUETTI Elite 200 V2 (2,073 Wh) | 1,762 Wh | 29.4 hours | 44.1 hours | 22.0 hours | 117 hours | 13.2 hours, if it can start the pump |
| EcoFlow DELTA 2 Max (2,048 Wh) | 1,741 Wh | 29.0 hours | 43.5 hours | 21.8 hours | 116 hours | 13.1 hours, if it can start the pump |
| EcoFlow DELTA Pro 3 (4,096 Wh) | 3,482 Wh | 58 hours | 87 hours | 43.5 hours | 232 hours | 26 hours, if it can start the pump |
A 1 kWh station is therefore a realistic overnight CPAP battery without the humidifier, and a tight but usable one-day fridge battery. A 2 kWh station is the more comfortable fridge-plus-internet kit for a full day and night. A 4 kWh-class unit is what you want if the outage may last a weekend or you will add a pump to the same battery.
At a glance
-
EcoFlow RIVER 3 PlusEFRIVER3PLUS · 286 Wh · 600 W · LiFePO4
-
EcoFlow DELTA 3 PlusEFDELTA3P · 1,024 Wh · 1,800 W · LiFePO4$719.00ShippingPrice as of Nov 23, 2026, 3:45 AM ET
-
BLUETTI Elite 200 V2Elite 200 V2 · 2,073 Wh · 2,600 W · LiFePO4$999.00ShippingPrice as of Nov 23, 2026, 3:45 AM ET
-
EcoFlow DELTA 2 MaxEFD350 · 2,048 Wh · 2,400 W · LiFePO4
Compare the mid-size stations
| Product | Capacity | Output | Chemistry | AC charge | Solar in | Price |
|---|---|---|---|---|---|---|
| EcoFlow RIVER 3 Plus EcoFlow | 286 Wh | 600 W | LiFePO4 | 60 min | 220 W | Check price |
| EcoFlow DELTA 3 Plus EcoFlow | 1,024 Wh | 1,800 W | LiFePO4 | 56 min | 1,000 W | $719.00 |
| Jackery Explorer 1000 v2 Jackery | 1,070 Wh | 1,500 W | LiFePO4 | 102 min | 400 W | $559.00 |
| BLUETTI AC180 BLUETTI | 1,152 Wh | 1,800 W | LiFePO4 | — | 500 W | $549.00 |
| Anker SOLIX C1000 Anker | 1,056 Wh | 1,800 W | LiFePO4 | 58 min | 600 W | $599.99 |
| BLUETTI Elite 200 V2 BLUETTI | 2,073 Wh | 2,600 W | LiFePO4 | 84 min | 1,000 W | $999.00 |
| EcoFlow DELTA 2 Max EcoFlow | 2,048 Wh | 2,400 W | LiFePO4 | — | 1,000 W | Check price |
| Jackery Explorer 2000 v2 Jackery | 2,042 Wh | 2,200 W | LiFePO4 | 105 min | 400 W | $999.00 |
-
EcoFlow RIVER 3 Plus EcoFlow
- Capacity
- 286 Wh
- Output
- 600 W
- Chemistry
- LiFePO4
- AC charge
- 60 min
- Solar in
- 220 W
-
EcoFlow DELTA 3 Plus EcoFlow
- Capacity
- 1,024 Wh
- Output
- 1,800 W
- Chemistry
- LiFePO4
- AC charge
- 56 min
- Solar in
- 1,000 W
-
Jackery Explorer 1000 v2 Jackery
- Capacity
- 1,070 Wh
- Output
- 1,500 W
- Chemistry
- LiFePO4
- AC charge
- 102 min
- Solar in
- 400 W
-
BLUETTI AC180 BLUETTI
- Capacity
- 1,152 Wh
- Output
- 1,800 W
- Chemistry
- LiFePO4
- AC charge
- —
- Solar in
- 500 W
-
Anker SOLIX C1000 Anker
- Capacity
- 1,056 Wh
- Output
- 1,800 W
- Chemistry
- LiFePO4
- AC charge
- 58 min
- Solar in
- 600 W
-
BLUETTI Elite 200 V2 BLUETTI
- Capacity
- 2,073 Wh
- Output
- 2,600 W
- Chemistry
- LiFePO4
- AC charge
- 84 min
- Solar in
- 1,000 W
-
EcoFlow DELTA 2 Max EcoFlow
- Capacity
- 2,048 Wh
- Output
- 2,400 W
- Chemistry
- LiFePO4
- AC charge
- —
- Solar in
- 1,000 W
-
Jackery Explorer 2000 v2 Jackery
- Capacity
- 2,042 Wh
- Output
- 2,200 W
- Chemistry
- LiFePO4
- AC charge
- 105 min
- Solar in
- 400 W
Safety: transfer switches and indoor use
Plug refrigerators, CPAPs, pumps, and chargers directly into the station's AC outlets when you can. For selected house circuits, use a transfer switch or interlock and follow the manufacturer's wiring instructions for that model. Keep the station dry, leave its vents clear, and test your setup on a working day, not during the storm.
Fuel generators are a different product. If you add one later to recharge a station, run the generator outdoors only, at least 20 feet from doors and windows, and keep a CO alarm inside the house.
Frequently asked questions
Frequently asked questions
How many watt-hours do I need to run a refrigerator during an outage?
Plan from average draw, not only the 150 W a compressor may use while it is running. If that compressor runs about 40% of the time, the average is about 60 W. Using 85% of rated watt-hours as usable energy, a 1,024 Wh station lasts about 14.5 hours and a 2,048 Wh station lasts about 29 hours. You still need enough continuous and surge watts to start the compressor.
Can a portable power station run a CPAP overnight?
Yes, if the battery is large enough for the machine's average draw. Without a heated humidifier many CPAPs average about 40 W, so an 8-hour night needs about 376 Wh of usable energy and a 1 kWh station can cover two nights. With a heated humidifier, plan closer to 80 W, which is about one long night on a 1 kWh station. Prefer a model with a published UPS or EPS switchover and test it before you rely on it.
What size power station do I need for a sump pump?
Start with the pump's running and starting watts, which are often 800–1,500 W running and two to three times that at start-up. Choose a station whose continuous and surge ratings clear both numbers. Runtime then depends on how often the pump cycles; at 800 W for 10 minutes each hour, the average is about 133 W, so a 2 kWh station lasts about 13 hours of that duty cycle if it can start the motor every time.
What does the 85% runtime rule mean?
We treat 85% of a station's rated watt-hours as usable energy to allow for inverter losses, then divide by the appliance's average watts. A 1,024 Wh station therefore has about 870 Wh usable. The remaining capacity is not wasted in every case, but planning at 85% keeps estimates from running long.
Do I need a transfer switch to use a power station at home?
Not if you plug appliances directly into the station's AC outlets. You do need a transfer switch or an interlock, installed by a licensed electrician, if you want the station to power built-in house circuits. Never back-feed the house by plugging the station into a wall outlet or dryer receptacle.
Is LiFePO4 better than NMC for home backup?
LiFePO4 (lithium iron phosphate) is the chemistry used by every station in this guide. Makers typically rate it for thousands of cycles to 80% capacity and it is the usual choice for equipment that may sit partly charged and then work hard during an outage. Some brands rate cycle life to 70% instead of 80%; we do not record a cycle-life figure in those cases.
How fast does a UPS switchover need to be for a CPAP or a computer?
Most home electronics keep running through a 10–20 ms switch from wall power to battery. A 30 ms switchover, which some older stations use, can still work, but you should test the specific device. These household EPS or UPS modes are not the same as a 0 ms online UPS unless the manufacturer publishes that figure, as Jackery does for the Explorer 5000 Plus's online UPS mode.
Can I recharge a power station with solar during a multi-day outage?
Yes, if your panels fit the station's maximum solar watts and its voltage window. A 1 kWh station with a 400–1,000 W solar input can refill in a few hours of good sun, but winter clouds will slow that down. Match the panel's open-circuit voltage to the station's published solar voltage range, and stay at or under the maximum solar wattage.